Xiamen Xingruijia Import and Export Co., Ltd. has been specializing in the sales of industrial control equipment spare parts for 20 years. For more ABB models, please refer to the product list . If you need other brands or models, please contact us. We have a variety of brands and models in stock, and we can purchase difficult to order models for you. We look forward to your inquiry!!!
First hand source//affordable price//Spot inventory!
•Shipping Port: Xiamen
•Manager: Rhonda
•E-mail: sales7@saulplc.com
•Tel/WhatsApp/Wechat: + 86-15359273796
•Ship to you via Fedex/DHL/TNT/UPS/EMS
•Package: Original packing with cartons
ABB ES2000-9725
The ABB ES2000-9725 (1SBT152000R9725) is a high-current electronic current sensor designed for measuring AC, DC and pulsating currents in industrial electrical systems.
It uses closed-loop Hall-effect technology to provide accurate current measurement with galvanic isolation between primary and secondary circuits. The sensor is designed for industrial applications requiring reliable current monitoring, electrical protection and power-system measurement.
The ES2000-9725 belongs to ABB's ES series of industrial current sensors and supports primary currents up to 2000 A RMS.
2. Technical Parameters
|
Parameter |
Specification |
|
Brand |
ABB |
|
Model |
ES2000-9725 |
|
Order Number |
1SBT152000R9725 |
|
Product Type |
Electronic Current Sensor |
|
Product Series |
ES Series |
|
Measurement Technology |
Closed-loop Hall Effect |
|
Rated Primary Current |
2000 A RMS |
|
Measuring Range |
±3000 A peak |
|
Secondary Output Current |
400 mA |
|
Supply Voltage |
±15 to ±24 V DC |
|
Accuracy at 25°C |
±0.5% |
|
Linearity |
≤0.1% |
|
Bandwidth |
DC–100 kHz |
|
Response Time |
≤1 μs |
|
Galvanic Isolation |
Yes |
|
Primary Conductor Opening |
64 mm |
|
Dielectric Strength |
4 kV RMS |
|
Operating Temperature |
-20 to +70°C |
|
Storage Temperature |
-40 to +85°C |
|
Dimensions |
170 × 136 × 52 mm |
|
Weight |
Approximately 1.5 kg |
3. Core Functions
-
AC Current Measurement: Measures alternating current in industrial power systems.
-
DC Current Measurement: Supports continuous current monitoring in DC electrical circuits.
-
Pulsating Current Measurement: Measures fluctuating and pulsed current signals.
-
Galvanic Isolation: Electrically isolates primary and secondary circuits to improve measurement safety.
-
Current Signal Conversion: Converts primary current into a proportional secondary output current.
-
Real-Time Monitoring: Provides measurement signals for industrial control and monitoring equipment.
4. Product Features
-
Closed-loop Hall-effect measurement technology.
-
Supports AC, DC and pulsating current measurement.
-
High rated primary current of 2000 A RMS.
-
Measuring range up to ±3000 A peak.
-
High measurement accuracy and excellent linearity.
-
Wide DC-to-100 kHz measurement bandwidth.
-
Galvanic isolation between primary and secondary circuits.
-
Self-extinguishing plastic housing.
-
Built-in protection against measuring circuit short circuits and open circuits.
-
Designed for demanding industrial electrical environments.
5. Structural Composition
The ABB ES2000-9725 consists of several major functional components:
-
Magnetic Measurement Core: Detects the magnetic field generated by the primary current.
-
Hall-Effect Sensor: Measures magnetic flux and converts it into an electrical signal.
-
Electronic Compensation Circuit: Maintains closed-loop measurement accuracy.
-
Primary Current Conductor Opening: Allows the primary conductor or busbar to pass through the sensor.
-
Secondary Output Interface: Provides the proportional current output signal.
-
Power Supply Interface: Supplies the required operating voltage to the internal electronics.
-
Insulating Housing: Protects internal components and provides electrical insulation.
6. Typical Applications
The ES2000-9725 is widely suited to industrial electrical measurement and monitoring applications, including:
-
Industrial motor current monitoring.
-
Variable frequency drive systems.
-
Power converters and inverter equipment.
-
Power generation and distribution systems.
-
Industrial rectifier equipment.
-
Renewable energy conversion systems.
-
High-current DC power supplies.
-
Electrical protection and monitoring systems.
-
Heavy industrial manufacturing equipment.
7. Maintenance Considerations
-
Verify the model number ES2000-9725 and order code 1SBT152000R9725 before installation.
-
Check the primary conductor diameter and ensure it fits the 64 mm opening.
-
Confirm the correct DC supply voltage and polarity.
-
Inspect secondary output connections for loose contacts or oxidation.
-
Ensure that the primary current conductor follows the indicated current direction.
-
Avoid exceeding the specified primary current and operating temperature limits.
-
Check the sensor output signal periodically to maintain measurement accuracy.
-
Disconnect the relevant power supply before performing maintenance on electrical connections.
8. Overall Evaluation
The ABB ES2000-9725 (1SBT152000R9725) is a high-performance industrial current sensor based on closed-loop Hall-effect technology. With a rated primary current of 2000 A RMS, a measurement range of ±3000 A peak and galvanic isolation, it provides reliable current measurement for demanding industrial electrical applications.